Hi all,

iDirect's Uplink Control Process (UCP) can adjust changing weather attenuation through power adjustment on the upstream. However on downstream there is no such feature available.
I heard that usually an external UPC is used to compensate rain fade at the HUB's TX path.
Does anyone know how that works in detail? What hardware is used? I assume it is a done via an adjustable attenuator, but cannot find any details on the internet?

Can somebody point me into the right direction?

Thanks a lot, Mike.
Back to top
« Last Edit: Nov 26th, 2009 at 11:36am by Admin1 »  
 
IP Logged
 
Admin1
YaBB Admin
★★★★★
Offline



Posts: 1192
Reply #1 - Nov 26th, 2009 at 11:52am  
One (simplified) way to do uplink power control at the hub on the outlink downstream carrier:

You need a beacon receiver to measure the downlink path loss.
Compare with nominal and multiply by a numerical factor related to the downlink versus uplink frequency attenuations.
Apply the result to a variable attenuator in the uplink transmit path.

It sounds easy but is actually difficult and needs to be done with great caution and strict limits. There are considerable problems with calibration, tracking, equipment and cable gain drift with temperature, fast scintillation, step changes due to poor connectors, interference, sun noise, faults etc. Under no circumstances do you want the clear sky uplink power increasing spontaneously by 10dB due to some software interaction with an anomaly condition and overloading the satellite transponder.

Check with the satellite owner for rules that you must comply with regarding UPPC operation.

For equipment read here  Miteq UPPC D-218 as a typical example.

Best regards, Eric.
Back to top
 
WWW  
IP Logged
 
mike123
Member
★★
Offline



Posts: 3
Reply #2 - Nov 26th, 2009 at 12:28pm  
Thank's for the fast and comprehensive input, Eric.
Back to top
 
 
IP Logged
 
Ex Member
Ex Member


Reply #3 - Nov 26th, 2009 at 1:15pm  
Agree w/ Eric. UPC for the outbound (most larger earth stations/terminals are equipped with them).
Back to top
 
 
IP Logged
 
Agor
Member
★★
Offline



Posts: 48
Reply #4 - Nov 27th, 2009 at 7:39pm  
Adding DVB-S2 ACM is even better, as it takes care for the remote terminal's reception in rain conditions, etc.
Back to top
 
 
IP Logged
 
Scout
Senior Member
★★★
Offline



Posts: 86
Reply #5 - Dec 2nd, 2009 at 9:58pm  
Using the ACM capability on iDirect is a great feature, but I think it's important to keep the two as separate concerns.
the UPC on the hub should be controlled separately from the ACM feature.  If you use the ACM to compensate for all hub side fade, then given a scenario of a severe fade hub side, all remotes would end up using the worst MODCOD (modulation and coding) this would be very inefficient. 
If you implement the correct hub power control using external devices, you maintain the benefits of ACM by having it relate to individual remotes receive performance rather than the hub Tx performance.  ACM was not designed to compensate for lack of UPC at a hub location.
Although a solution of sorts, I think it would be far more beneficial and efficient to utilize the correct UPC hub side.
Just my 2 cents.
Back to top
 
 
IP Logged
 
Agor
Member
★★
Offline



Posts: 48
Reply #6 - Dec 3rd, 2009 at 2:01pm  
I agree. I suggested to add ACM, not to use ACM instead of UPC.