Logo

Satellite Internet Forum.
Please note that this forum is now READ ONLY and closed for login and changes
The new forum is here Space and Satellite Communications forum

Welcome, Guest.
Welcome to this satellite broadband discussion forum.  Wherever you are and whatever your problem we are here to help each other. Connecting to the internet via satellite is not always easy but is critically important to those in remote places or with poor terrestrial infrastructure.  Both service providers and customers are encouraged to contribute.  Read the Forum rules.
      Satellite internet forum          

Rx Sync problem between Old Hub and Newer RCST

(Read 3219 times)
dewole10
Ex Member


Dec 5th, 2011 at 12:04pm  
good day,

a client of mine has a Linkstar DVB-S1 hub that's working fine with several remotes. We just purchased a used RCST that was decommissioned from a different network and when we enter the parameters for our network, the RCST loses Rx Sync in less than 2 minutes.

When first plugged in, the Rx syncs with a good BER but in a couple of seconds, the BER becomes really high and the RCST shows some message about the RNCC possibly kicking it. It then goes on to try another bootconf which of course does not work.  

Versions on new RCST
0x239A7 SW rcst4s-2.3.0101.term.exe (PE)  ()
0x239A7 FW rcst4.16190707L.xilinx.dat () rcst4.15250706L.xilinx.dat (PE)

Version on other RCSTs connected to the Hub fine is
SW: rcst4-1.0.8.17p2.term.exe
FW: rcst4.16100106L.xilinx.dat

I have two questions:

1. how can we downgrade the firmware and software directly i.e. via the ethernet interface rather than over-the-air
2. what is the correct procedure for adding a previously used RCST to a linkstar hub? (my client inherited the network with little documentation so i can't really be sure he is doing the right thing)

thank you for your anticip.ated help.

Dewole
Back to top
« Last Edit: Dec 5th, 2011 at 4:17pm by N/A »  
 
IP Logged
 
dewole10
Ex Member


Reply #1 - Dec 5th, 2011 at 3:35pm  
PS:
The error displayed on the RCST is

....
Rx Synced
Rx Sync lost
RCST is either unable to synchronize,
Or has not been validated by the RNCC
Trying the next Network Boot Config
........

Can someone please assist me with the correct steps to validate a newly acquired RCST?

Thanks a lot.
Back to top
 
 
IP Logged
 
FeedElAzim
Ex Member


Reply #2 - Aug 5th, 2012 at 6:34pm  
Have the customer/installer perform the command rcstlockinfo through a telnet session.
I the output says something like "...locked through telnet session" then you would need to contact the previous provider for the pincode to unlock the rcst.
Are the bootparameters also in sync with the Hub settings?
Back to top
 
 
IP Logged