Advertisment: Broadband via satellite
Advertisment: Worldwide satellite services from Ground Control Company

www.satsig.net

Satellite Internet Forum.

Welcome, Guest.        Forum rules.
      Home            Login            Register          
Pages: 1

NMS GUI

(Read 2574 times)
LAKHDARIAHUB
Member
★★
Offline



Posts: 18
Dec 30th, 2008 at 3:10pm  
Hello for all
I have the following problem
With iBuilder or iMonitor i can't connect to the NMS data base, when I tray to connect I have "please wait» message only .
I connect to the NMS with putty all services are running well
can You help me please.
thank you
Back to top
 
 
IP Logged
 
Ex Member
Ex Member


Reply #1 - Dec 30th, 2008 at 6:52pm  
iDS version?

Please elaborate when you say "connect to the NMS database?"  

Does it happen when right click a remote or a line card and select "modify?" (to modify its properties?)

Have you restarted nms services in an effort to resolve?  If so, have your rebooted your NMS (full reboot)?
Back to top
 
 
IP Logged
 
LAKHDARIAHUB
Member
★★
Offline



Posts: 18
Reply #2 - Dec 31st, 2008 at 8:57am  
Quote:
iDS version?

Please elaborate when you say "connect to the NMS database?"  

Does it happen when right click a remote or a line card and select "modify?" (to modify its properties?)

Have you restarted nms services in an effort to resolve?  If so, have your rebooted your NMS (full reboot)?

Thank you for your reply
First, our version is: 6.0.9
We have rebooted the NMS soft ( I need to know how to make full reboot)
When we tray to connect with iBuilder or iMonitor
We have only this message "please wait , loading data"
And stol forever This message.

Back to top
 
 
IP Logged
 
Ex Member
Ex Member


Reply #3 - Dec 31st, 2008 at 12:18pm  
If you can putty to it, just type reboot from the command line.  That command will reboot the entire box and not just the server processes.  I am not certain that will help you, but it is worth a try. 

Help me understand your situation.  Are you saying that when you initially try to connect with iBuilder (just after you authenticate?) you see this?  So you are not even able to log in with iBuilder? iMonitor behaves the same way?

If that is the case, I would seriously consider uninstalling your GUIs and re-installing them.  Check any windows firewall settings as well.  Something (such as a Win Firewall) may be denying you.   I would almost consider the GUI uninstall BEFORE you reboot the box entirely. 

M
Back to top
 
 
IP Logged
 